Key Digital KD-VW4x4ProK handleiding
Handleiding
Je bekijkt pagina 27 van 36

521 East 3
rd
Street Mt. Vernon, NY 10553 • www.keydigital.com
Rev 1.1 – Dec, 2022
27
TCP/IP and RS-232 Commands
TCP/IP Connection Protocol
• Default IP address = 192.168.1.239
• TCP/IP Port Number = 23
• Notes: Use Raw / Other service, not Telnet
Maximum of one TCP/IP socket supported at a time.
Simultaneous TCP/IP and web sockets are supported. Multiple web sockets are supported.
RS-232 Connection Protocol
• Baud Rate = 57,600 bits per second as default
• Data Bits = 8
• Stop Bits = 1
• Parity = None
• Flow Control = None
• Carriage Return = Required at end of each string
Notes:
• Commands are not case-sensitive
• Spaces are shown for clarity; commands should NOT have any spaces
• After a new command is received, a prompt should be sent back
Help Command (H). Returns entire API in readable format:
-------------------------------------------------------------------------
-- Key Digital Systems HELP --
-------------------------------------------------------------------------
-- KD-VW4x4ProK F/W Version : 1.18 --
-- --
-- H : Help --
-- STA : Show Global System Status --
-- PF : Power Off --
-- PN : Power ON --
-- --
-- Video Input Setup Command : ( xx=[01~04,A=All] ) --
-- SPI xx ON/OFF : Set Input xx ON/OFF --
-- --