TCP/IP and RS-232 Commands
TCP/IP Connection Protocol
Default IP address = 192.168.1.239
TCP/IP Port Number = 23
Notes: Use Raw / Other service, not Telnet
Maximum of one TCP/IP socket supported at a time.
Simultaneous TCP/IP and web sockets are supported. Multiple web sockets are supported.
RS-232 Connection Protocol
Baud Rate = 57,600 bits per second as default
Data Bits = 8
Stop Bits = 1
Parity = None
Flow Control = None
Carriage Return = Required at end of each string
Notes:
Commands are not case-sensitive
Spaces are shown for clarity; commands should NOT have any spaces
After a new command is received, a prompt should be sent back
Help Command (H). Returns entire API in readable format:
-------------------------------------------------------------------------
-- Key Digital Systems HELP --
-------------------------------------------------------------------------
-- KD-VW4x4ProK F/W Version : 1.18 --
-- --
-- H : Help --
-- STA : Show Global System Status --
-- PF : Power Off --
-- PN : Power ON --
-- --
-- Video Input Setup Command : ( xx=[01~04,A=All] ) --
-- SPI xx ON/OFF : Set Input xx ON/OFF --
-- --