BUILDING IN
Do not hold or carry the appliance by the door handle. The door handle cannot hold the weight of the
appliance and may break off.
1. Carefully push the microwave into the box, making sure that it is in the centre.
2. Open the door and fasten the microwave with the screws that were supplied.
Nie wolno trzymać ani przenosić urządzenia trzymając za klamkę drzwi. Klamka
drzwi nie utrzyma ciężaru urządzenia i może pęknąć.
1. Ostrożnie wepchnąć kuchenkę mikrofalową do wnęki, upewniając się, że jest na
środku.
2. Otworzyć drzwiczki i przymocować kuchenkę mikrofalową dostarczonymi śrubami.
Zabudowa
Całkowicie włożyć urządzenie i wyśrodkować.
Nie wolno zginać kabla przyłączeniowego.
Przykręć urządzenie na swoje miejsce.
15
Fully insert the appliance and centre it.
Do not kink the connecting cable.
Screw the appliance into place.
Important information with plug
Electrical connection
The appliance is fitted with a plug and must only be connected to a properly installed earthed socket.
Only a qualified electrician who takes the approriate regulations into account may install the socket or
replace the connecting cable. If the plug is no longer accessible following installation, an all-pole isolating
switch must be present on the installation side with a contact gap of at least 3 mm. Contact protection must
be ensured by the installation.
Fuse protection: see instructions for use-technical data.
Important information without plug
The appliance is designed to be permanently installed with a three-pin power cord and may only be connected
by a licensed expert in accordance with the connection diagram.
Only a qualified electrician who takes the relevant regulations into account may may replace the power cord.
Do not use multiple plugs, power strips or extensions. Overloading causes a risk of fire.
If the connection is no longer accessible following installation, an all-pin isolating switch with a contact
gap of at least 3 mm must be provided.
Connect the wires of the mains power cord in accordance with the following colour coding:
Green and yellow - Earth wire <(E)
Blue - Neutral wire (N)
Brown - Live (L)
Great Britain and Australia:
Do not connect the appliance using a 13A plug or protect it with a 13A fuse. The appliance must be protected
using a fuse that is rated 16A or higher. The appliance must be disconnected from the power supply during
all installation work. When the appliance is installed, protection must be provided against accidental contact