27
NG (natural gas) connection
1- G1/2 Nipple)
2- Silicon seal
3- G1/2 NG hose (EN 14800 compliant natural gas
hose)
Figure 11
If your equipment is set for natural gas, get the equipment connected by the installation firm of the concerned
natural gas distribution company. Natural gas connection of your equipment is ½”. If you desire to convert
your equipment from LPG to natural gas or from natural gas to LPG, contact with the nearest service centre
and make them do the required gas conversion settings. u.
SEALING INSPECTION
Open the pressure-reducing valve or natural gas valve and control by application of much foamy water on
the connection to find out any gas leakage.
Never control by ame.
FINAL INSPECTION
1. Plug the power cable into the socket and activate the fuse of the equipment.
2. Control the functions.
LPG-NG / NG-LPG conversion
Figure 12 Figure 12.1 Figure 12.2 Figure 12.3
Figure 12.4
Remove the burner cover and burner as shown in in the Figure 12.
Remove the injector by help of 7’s socket screwdriver as shown in the Figure
12.1
Fix the injector (D) to be converted as shown in the Figure 12.2. (see table 1).
Replace the burner as shown in the Figure 12.3.
Turn on the burners respectively after conversion and remove the button
on the control panel and set the flame length by tightening or loosening the
screw on the gas valve (12.4 cock) or in the valve shaft.