IMPORTANT
• The bulb must be replaced by the manufacturer, its service
agent or similarly qualified persons.
• Always switch off the electricity supply before carrying
out any operations on the appliance. When handling bulb,
make sure it is completely cool down before any direct
contact to hands.
• When handling globes hold with a cloth or gloves to ensure
perspiration does not come in contact with the globe as this
can reduce the life of the globe.
NOTE:
• Before changing the lights, make sure that the appliance is plugged off.
Changing the lights:
• Remove the appliance and its grease filter.See step1.
• Disconnect the terminal of the light connecting wire .See step2.
• Disassembly the light strip:prise the translucent plate,take out the shell of light strip upwardly,
unscrew 2pcs screws ST3*6mm of the tension disc and remove the circuit board.See from
step3 to step6.
• Apply the reverse procedure to reinstall the light.
• ILCOS D code for this lamp is: DSS-3.5/65-S-320/45.2
– LED modules– rectangle lamp
– Max wattage: 1×3.5 W
– Voltage range: DC12V
– Dimensions:
BULB REPLACEMENT
Step 1 Step 2~6
The translucent place is stick
to the appliance shell.