DIRECT WIRE - U.S.A. ONLY
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Improper connection of aluminum house wiring and copper appliance leads can result in
an electrical hazard or fire. If the home has aluminum wiring, only use connectors designed
and UL listed for joining copper to aluminum and precisely follow the manufacturer's
recommended procedure. Aluminum-to-Copper connections must conform with local
codes.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to do so can result in death, fire or electrical shock.
Be sure your appliance is properly installed and grounded by a qualified technician. Ask
your dealer to recommend a qualified technician or an authorized repair service.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker box (or fused disconnect)
through flexible or nonmetallic sheathed, copper or aluminum cable.
Allow at least 6 ft (1.8 m) of slack in the line so that the range can be moved if servicing
is ever necessary.
A UL listed conduit connector must be provided at each end of the power supply cable
(at the range and at the junction box).
Wire sizes and connections must conform with the rating of the range.
The tech sheet and wiring diagram are included with the range.
This appliance is manufactured with the chassis connected to the neutral by a green
ground jumper wire. After making sure that the power has been turned off, connect the
flexible conduit from the oven to the junction box using a UL listed conduit connector. The
Grounded Neutral and Ungrounded Neutral Graphics on the following pages and the
instructions provided, present the most common way of connecting the ovens. Your local
codes and ordinances, of course, take precedence over these instructions. Complete
electrical connections according to local codes and ordinances.
3-WIRE CONNECTION (GROUNDED NEUTRAL)
WARNING
Electrical Shock Hazard
Grounding through the neutral conductor is prohibited for new branch-circuit installations
(1996 NEC); mobile homes; and recreational vehicles, or in an area where local codes
prohibit grounding through the neutral conductor. For installations where grounding
through the neutral conductor is prohibited, see the Ungrounded Neutral graphic.