A Access Panel to Electrical Supply
Connection
B Power Cord Opening
C Recessed Area
3. Install a UL listed strain relief to the power cord opening in the support bracket, and fully
tighten the strain relief nut.
4. Feed the power supply cord through the strain relief. Allow enough slack to easily attach
the wiring to the terminal block.
A Ground Screw
B Terminal Block
C Jumper Wire
D Power Cord Wires
E UL Listed Strain Relief
5. Remove the green jumper wire from under the ground screw and replace with the green
wire from the power cord and tighten ground screw.
6. Loop the green jumper wire removed from the ground screw back onto its end that is
fastened to the center post on the terminal block.
7. Use 5/16" nut driver to connect the neutral (white) wire to the center terminal block post
with one of the 10-32 hex nuts.
8. Using 10-32 hex nuts, connect the red and black wires from the power cord to the outer
posts of the terminal block with the corresponding red and black wires from the range.
9. Tighten the hex nuts completely, and then verify the connection.
NOTE: For power supply cord replacement, use only a power cord rated at 250 volts
minimum, 50-amps that is marked for use with nominal 1 & 3/8" (3.5cm) diameter
connection opening, with ring terminals and marked for use with ranges.
10. Position the lower part of the strain relief under the power cord and tighten the strain
relief screws.
NOTE: Before tightening, make sure the strain relief is positioned over the cord and