Conguration of the multiple
line system
A multiple line system comprises
individual lines which are linked
together by two cores. The lines
are connected at the bus video line
rectier using terminals SaV and SbV.
In multiple line systems, speech and
video connections are possible from
one line to another. To generate a
multiple line system, the bus line
rectier accessory ZBVG650-… is
required in one of the bus video line
rectiers.
In each bus video line rectier,
the bus video line rectier acces-
sory ZBVNG650-… is required.
Differentiation between
line 1 and line 2 …
The lines are consecutively num-
bered using the address switch
“Adr.“ at the bus video line rectier
BVNG650-… Up to 15lines can be
linked via the SaV and SbV cores.
The bus video line rectier is
connected via the bus distributor
BVVU650-…
At the bus video line rectier, a
bus line rectier can be connected
directly via the cores Sa and Sb in
order to link a line with In-Home:
Audio. During installation, ensure
that each line is laid in a separate
cable.
Functions applicable across indi-
vidual lines
Door calls, selective door dialling and
switching and control functions can
also be used across individual lines.
Internal speech communication and
call forwarding between users is only
possible within a line.
Conductor length between the
lines
The admissible conductor lengths
within a line are identical to those
in a single line system. In addition,
the admissible conductor length
between the bus video line rectiers
must be taken into account.
This must be no more than 150m
(45dB) between the most distant
bus video line rectiers (using
J-Y(St)Y cable with 0.8mm diam-
eter).
As only data exchange takes place
between the bus video line rectiers,
i.e. no current ows, it is possible
to achieve a range of up to 300m
using a CAT installation cable (e.g.
CAT5).
In a multiple line system comprising
only 2lines, connection between
the two bus video line rectiers is
possible without bus distributor
BVVU650-…
The maximum admissible lengths
within a line and the attenuation
values continue to be valid.
When installing, ensure without fail
that the camera branch and monitor
branch are not laid in the same
cable. Forward and return lines to a
bus telephone with video must not
be laid in the same cable.
Otherwise, picture disturbance may
result.