J-Y(St)Y
Camera branch 1 max. 150 m/492 ft
Monitor branch 1 max. 150 m/492 ft
Attenuation max. 45 dB
Attenuation max. 55 dB
Camera branch 2 max. 150 m/492 ft
Monitor branch 2 max. 150 m/492 ft
Single line system with bus distributor and ZBVNG650-…
Conductor length with bus dis-
tributor and ZBVNG650-…
The ZBVNG650-… accessory ampli-
es the video signal, so permitting
greater attenuation in the camera
branch and monitor branch. To do
this, the inserted jumper card in
the BVNG650-… is removed and
the ZBVNG650-… inserted in the
same slot.
The following information relating
to conductor lengths refers to one
camera branch and one monitor
branch. If several branches are
installed within a line, the informa-
tion is applicable to each branch.
Whichever value (attenuation or
conductor length) is reached rst is
applicable as a specication of the
admissible value.
The limiting values must be adhered
to for each of the branches.
Conductor length
Conductor material J-Y(St)Y cable
with 0.8mm diameter:
• max. 150m from the bus video
line rectier to the most distant user
in the monitor branch
• max. 150m from the bus video
line rectier to the most distant user
in the camera branch
• max. 45 dB attenuation from the
bus video line rectier to the most
distant user in the camera branch
• max. 55 dB attenuation from the
bus video line rectier to the most
distant user in the monitor branch
With a core diameter of 0.6mm,
the range is halved.
Within the line, the maximum length
of the conductor material must not
exceed 1,500m.