DoorCom Analog DCA650-…
Functional
Calling and speech between the
door station and the connected a/b
telephones of a telephone system.
The DoorCom-Analog DCA650-02
is able to forward the call from up
to 31 bell buttons to a telephone
system. The DCA650-02 calls the
PBX extensions of the telephone
system using dual-tone multiple
frequency dialling DTMF. Audio and
video privacy of existing calls from
other telephones is assured. The
function for door release and light
switching via DTMF symbols is pos-
sible at connected a/b telephones in
the telephone system.
Connection of other bus indoor
devices with colour display when
looping through from one device to
the next.
Other bus door loudspeakers with
video are connected with bus
video distributors BVVU650-… or
BVVS650-…
Supplementary functions
• Internal speech communication
between bus indoor devices is only
possible internally within the same
line.
• Connection of bus telephones
AIB150-…/BTS/BTC/BFC850-… or
devices for switching and control
functions via bus audio decoupler
BAA650-…
For more information, see
page68
• Switching and control functions
are possible with the bus switching
modules BSM/BSE/BEM650-…,
feedback to the deluxe bus indoor
devices can be programmed.
For more information, see
page123
• Bus secondary signal unit
BNS750-… possible.
For more information, see
page132
• Parallel door and storey call
Up to 8 bus indoor devices with
colour display can be called simulta-
neously via one call button. From the
second bus telephone VIB150-…/
BTSV/BTCV/BFCV850-… each
device must be additionally supplied
at terminals +M/–M.
Only possible within a line.
• Selective dialling of the door
station possible via additional free
buttons.
• Video memory function
possible with bus indoor devices
BVPS/BVPC850-… and BTCV/
BFCV850-…, additional installation
required (for BTCV/BFCV850-…).
Remarks
a) The TR603-… (12VAC, 1.3A)
can supply the door release, camera
heating and max. 30 bus call button
modules.
Where more bus call button modules
are used, an additional TR603-… is
required for the door release.
b) Door release/light contact load
in the bus video line rectier
BVNG650-… max.15VAC,
30VDC, 2A.
c) Door release 12VAC, use at least
20Ohm (e.g. TÖ615-…).
Weitere Informationen siehe
Seite126
d) Conductor length bus indoor
device – storey call button ERT max.
50m.
e) When using the video memory
module, the bus telephone BTCV/
BFCV850-… must be supplied
by an additional direct voltage
(20–30VDC, 350mA). VNG602-…
can be used for this purpose.
For more information, see
page128
g) Every DCA650-… must be sup-
plied via a separate TR603-…
If the predecessor model DCA650-0
is used, the operating mode switch
of the BNG/BVNG650-… must be in
position1. The maximum distance of
the DCA650-… from the TR603-…
is 20m.