Jung SITMA5073 handleiding
Handleiding
Je bekijkt pagina 118 van 140

7.2 Programming – Plug+Play
Basics
Plug+Play programming offers the
opportunity for those without pro-
gramming experience to commission
an In-Home bus system. The entire
installation of all users must have
been completed. The housings of
the bus telephones must not yet
have been closed. The Plug+Play
mode must be activated at the bus
line rectier. By being connected
to the bus door loudspeaker, the
call buttons at the bus call button
module are assigned a consecutive
number. The bus telephones are
subsequently locked onto the base
plates in this sequence.
Conditions for Plug+Play:
• Plug+play-programming is only
possible with new bus indoor
devices, new bus door loudspeaker
BTLM650-04/BTLE050-03, bus call
button modules BTM650-01, -02,
-03, -04, BRMA050-01 and bus line
rectiers BNG/BVNG650-…
• Plug+play-programming only
works for bus indoor devices within
any one line.
• Several door stations within a line
are programmed simultaneously
with the same assignment, e.g. two
door stations with 4call buttons
have the same assignment.
Where there is more than one bus
call button module, numbering of
the call buttons takes place in the
same sequence in which the mod-
ules are connected to each other via
the IN/OUT connections.
Conditions for Plug+Play:
• Install the system in accordance
with the wiring diagram.
• Connect the base plates of the bus
telephones, do not yet close the
housings.
• With Smart Gateway Mini/Siedle
Scope, do not yet connect the base
station to the In-Home bus.
• Connect the Jung modules to each
other using the supplied connecting
cables. The terminal block must not
yet be plugged in.
• At the door station, document the
assignment of call buttons or if pos-
sible inscribe straight away.
• Set the bus line rectier to the
Plug+Play mode by holding down
the programming mode button for
5seconds. LED1 must stay on con-
tinuously.
• Mount the bus telephones on the
base plates in the same sequence
as the assignment of call buttons.
(receiver down)
• With Smart Gateway Mini/Siedle
Scope, connect the base station to
the In-Home bus.
• Where a Jung indoor station is
used, plug in the terminal block.
• The storey call is audible briey
after appr. 7seconds as an acknowl-
edgement and the LED under the
call silencing button starts to ash.
The next bus telephone can then be
closed.
• After all the telephones have been
closed, at the bus line rectier press
the programming mode button. The
programming mode is switched off,
the programming of the system is
complete.
Reset Plug+Play:
All already connected bus tele-
phones must be locked into position
on the base plates.
• Switch off the supply voltage to
the bus line rectier.
• Disconnect terminals Ta and Tb
• Change the address of the bus
line rectier, e.g. from address1 to
address 2
• Hold down the Prog. mode button
for around 3seconds and switch on
the supply voltage of the bus line
rectier. After around 3seconds
release the button, wait until LED1
indicates the standard operating
mode again.
• Reconnect terminals Ta and Tb and
wait until the system has nished
running up.
• Pick up all bus telephones from the
base plates again.
• Return the address switch to its
original status, e.g. change from 2
to 1, and wait until the system has
nished running up. Check whether
all the bus telephones have been
picked up again. Plug+Play program-
ming can begin again.