Multiple line system
Functional
Calling and speech between the
door station and the connected bus
indoor devices. Automatic assign-
ment of the door release button
to the door station from which the
doorbell was last rung.
Other bus telephones are not able
to listen in to an existing call. Light
button for the light switching
function. Connection of a storey
call button (ERT) for calling from
an apartment door. Ring tones can
be selected for calls from the front
door, apartment door or internal
calls. Connection of additional bus
telephones or bus door loudspeakers
possible at the In-Home bus without
accessories.
In systems with more than 31users,
it is essential for a multiple line
system to be congured. A multiple
line system can also be used in
order to form storey door stations
or create functionally separate units
such as a doctor’s practice. Each line
has its own speech channel. Up to
160users can be called from one
door station. Instead of doorbell
buttons, the call can also be placed
via code lock module COM611-…
or display call module DRM612-…
In this case, up to 465users can be
called from one door station.
Supplementary functions
• Internal speech communication
between bus indoor devices is only
possible internally within the same
line.
• Switching and control functions
are possible with the bus switching
modules BSM/BSE/BEM650-…,
feedback to the deluxe bus indoor
devices can be programmed.
• Bus secondary signal unit
BNS750-… possible.
• Parallel door and storey call
Up to 4 AIB150-…/BTS/BTC/
BFC850-… devices can be called
simultaneously. With the parallel
switching accessory in devices BTC/
BFC850-…, the number can be
extended to a maximum of 8.
Only possible within a line.
For more information, see
page82
• Selective dialling of the door
station possible via additional free
buttons.
Remarks
a) The BNG650-… is able to supply
1 door release and max.20 bus call
button modules with LED lighting
BTM650-01, -02, -03 and -04.
With more than 20 illuminated bus
call button modules, an additional
TR603-… is required.
• Max. load of the bus door release
contact in the bus line rectier
BNG650-… 15VAC, 30VDC, 2A
• Max. load of light contact in the
bus line rectier 15VAC, 30VDC,
2A.
b) Door release 12VAC, use at least
20Ohm (e.g. TÖ615-…).
For more information, see
page80
• Current consumption bus call
button module 20mA at terminal
b/c.
c) Conductor length bus indoor
device – storey call button ERT
max. 50m.
e) One bus line rectier accessory
ZBVG650-… only is required in the
entire system.
f) If several BNG/BVNG650-… units
are installed in one system, their
addresses must differ.