Jung SI 4 AD handleiding

96 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 3 van 96
3
Conguration “Single line“
The In-Home bus: The Audio system
comprises a bus installation with
a two-core line permitting the
connection of up to 31users, e.g.
bus telephones, handsfree bus
telephones, door stations or devices
for switching and control functions.
Technically speaking, one device can
occupy more than one user.
The line has its own bus line rectier
for central functions such as speech,
door release or light switching.
The two cores assume the dual
functions of power supply and also
transmission of audio, switching
and control signals. Junction points
and branches are admissible at any
optional position in the line. In order
to connect more than 31users, sev-
eral Siedle In-Home: Audio lines can
be interconnected.
Conguration “Multiple line“
In-Home: Audio “Single line“ is
restricted to 31users; In order to
connect more than 31users, up to
15lines can be coupled together.
Each line requires its own bus
line rectier. Junction points and
branches are admissible at any
optional position in the line.
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualied
electrician. Failure to observe this
regulation could result in the risk of
serious damage to health or fatal
injury due to electric shocks.
• When working at the device,
observe the remarks relating to
mains cut-off.
Observe the DIN EN60065
standard! When establishing the
electronic connection, observe
the requirements of VDE0805 or
EN60950.
• The building installation must
include an all-pole mains switch
with a contact separation of at least
3mm.
Ensure maximum fusing of 16A
for the mains connection in the
building installation.
When planning large-scale
(complex) systems, the distributor
space required for the switch panel
mounting devices must be taken
into consideration in the distributor
planning process.
No external voltages >30VAC/DC
may be applied to bus users.
Devices with 230V connection
In accordance with DIN VDE0100
part410, section 411.1.3 attention
must be paid to ensuring a safe
separation between system lines
and the mains voltage; i.e. system
and mains cores must not be per-
mitted to touch! The system line
cable (extra-low safety voltage) must
be stripped back by the minimum
possible.
1 In-Home bus: Audio
System description
3 Safety remarks
Danger
“Siedle Systemtechnik“ and the
relevant logo are used to describe
devices, components or systems
which are not manufactured
and designed by Siedle but are
tted with Siedle technology. The
Systemtechnik logo guarantees tech-
nical compatibility with the Siedle
system world. Products identied
with “Siedle Systemtechnik“ may
therefore be used without restric-
tions as components of a Siedle
communication system.
Jung indoor stations in switch
design
Within the framework of a cooper-
ation agreement with the company
Jung, Siedle equips Jung indoor sta-
tions with “Siedle Systemtechnik“.
Indoor stations from Jung which
bear the Systemtechnik logo on
their components, their packaging
or the product information, are fully
compatible with Siedle technology.
They are integrated in this manual as
Siedle system components.
2 Siedle Systemtechnik
Jung indoor stations

Bekijk gratis de handleiding van Jung SI 4 AD, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkJung
ModelSI 4 AD
CategorieNiet gecategoriseerd
TaalNederlands
Grootte8414 MB