Jung FMGCR1700 handleiding

94 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 60 van 94
+
1.
2.
6. 7.
3.
4.
5.
eNet DRA devices need a 12 V pow-
er supply to supply the bus function
with power.
2. DRA RECEIVER MODULE
The DRA receiver module controls
the bidirectional communication
between the modules and the eNet
wireless system’s other compo-
nents. Except for one LED that
indicates operation, the receiver
module does not have any operat-
ing elements of its own. There is
no need to commission the DRA
receiver module separately; there
are no adjustable parameters.
The receiver module must not be
used together with the eNet server
within a DRA installation.
3. eNet SERVER AS THE
RECEIVER MODULE
The eNet server also has a receiv-
er module function meaning that
application modules can be con-
nected to it too. The eNet server
therefore replaces the DRA receiv-
er module in a DRA installation.
It is not possible to operate an eNet
server and DRA receiver module on
the same bus line at the same time.
4. DRA APPLICATION
MODULES
The application modules not only
contain electronics for commu-
nicating with the receiver mod-
ule, but also components for the
appropriate application. These
components might be sensor or
actuator modules with a single- or
multiple-channel design.
Each application module also con-
tains the necessary operating ele-
ments for its function, such as lo-
cal operating buttons, status LEDs
and operating mode switches.
eNet DRA devices provide the
same functions as in the other de-
signs. Commissioning either takes
place manually or using the eNet
server. If commissioning is carried
out using the eNet server, param-
eters can be set, connections to
other devices can be established,
and functions visualised. Con-
nected modules device software
1. 12 V DC / 2 A power supply
2. eNet server
3. Blind actuator, 1-gang DRA
4. Switching/blind actuator, 8/4-gang DRA
5. Switching actuator, 1-gang DRA
6. Additional eNet antenna
7. Additional WLAN antenna
can be updated without impairing
the other modulesability to com-
municate.
eNet DRA installation with eNet server DRA receiver module
121120 eNet _ Devices for installation in distributors