Jackson TempStar handleiding
Handleiding
Je bekijkt pagina 13 van 84

07610-003-61-42-U
6
Volts Phase Hz
Rinse Heater
Rating
Total Amps Typical Electrical Circuit
208 1 50 12 kW at 240 V 71 A 90 A
208 1 50 14 kW at 240 V 78 A 100 A
230 1 50 12 kW at 240 V 78 A 100 A
230 1 50 14 kW at 240 V 86 A 110 A
TempStar
208 3 50 12 kW at 240 V 45 A 60 A
208 3 50 14 kW at 240 V 49 A 70 A
230 3 50 12 kW at 240 V 48 A 60 A
230 3 50 14 kW at 240 V 53 A 70 A
380 3 50 12 kW at 380 V 29A 40 A
380* 3 50 14 kW at 380 V 34A 45 A
415 3 50 12 kW at 415 V 26 A 35 A
415 3 50 14 kW at 415 V 29 A 40 A
440 3 50 12 kW at 460 V 21 A 30 A
440 3 50 14 kW at 460 V 25 A 35 A
208 1 60 12 kW at 240 V 69 A 90 A
208 1 60 14 kW at 240 V 76 A 100 A
230 1 60 12 kW at 240 V 76 A 100 A
230 1 60 14 kW at 240 V 84 A 110 A
208 3 60 12 kW at 240 V 43 A 60 AP
208 3 60 14 kW at 240 V 47 A 60 A
230 3 60 12 kW at 240 V 46 A 60 A
230 3 60 14 kW at 240 V 51 A 70 A
460 3 60 12 kW at 480 V 22 A 30 A
460 3 60 14 kW at 480 V 25 A 35 A
* This model is wired in a wye conguration for the heaters.
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual
are for reference and may change without notice.
NOTE: Typical Electrical Circuit is based on:
1. 125% of the full amperage load of the machine.
2. Typical xed-trip circuit breaker sizes as listed in the NEC (Latest Edition).
NOTICE
i
Imbalanced
wild leg goes
to L3.
NOTICE
Imbalanced
wild leg goes
to L3.
NOTICE
Bekijk gratis de handleiding van Jackson TempStar, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Jackson |
| Model | TempStar |
| Categorie | Vaatwasser |
| Taal | Nederlands |
| Grootte | 12354 MB |







