07610-003-61-42-U
6
Volts Phase Hz
Rinse Heater
Rating
Total Amps Typical Electrical Circuit
208 1 50 12 kW at 240 V 71 A 90 A
208 1 50 14 kW at 240 V 78 A 100 A
230 1 50 12 kW at 240 V 78 A 100 A
230 1 50 14 kW at 240 V 86 A 110 A
TempStar
208 3 50 12 kW at 240 V 45 A 60 A
208 3 50 14 kW at 240 V 49 A 70 A
230 3 50 12 kW at 240 V 48 A 60 A
230 3 50 14 kW at 240 V 53 A 70 A
380 3 50 12 kW at 380 V 29A 40 A
380* 3 50 14 kW at 380 V 34A 45 A
415 3 50 12 kW at 415 V 26 A 35 A
415 3 50 14 kW at 415 V 29 A 40 A
440 3 50 12 kW at 460 V 21 A 30 A
440 3 50 14 kW at 460 V 25 A 35 A
208 1 60 12 kW at 240 V 69 A 90 A
208 1 60 14 kW at 240 V 76 A 100 A
230 1 60 12 kW at 240 V 76 A 100 A
230 1 60 14 kW at 240 V 84 A 110 A
208 3 60 12 kW at 240 V 43 A 60 AP
208 3 60 14 kW at 240 V 47 A 60 A
230 3 60 12 kW at 240 V 46 A 60 A
230 3 60 14 kW at 240 V 51 A 70 A
460 3 60 12 kW at 480 V 22 A 30 A
460 3 60 14 kW at 480 V 25 A 35 A
* This model is wired in a wye conguration for the heaters.
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual
are for reference and may change without notice.
NOTE: Typical Electrical Circuit is based on:
1. 125% of the full amperage load of the machine.
2. Typical xed-trip circuit breaker sizes as listed in the NEC (Latest Edition).
NOTICE