Jackson RackStar 44 handleiding
Handleiding
Je bekijkt pagina 44 van 80

37
07610-004-33-05-B
PARTS
VOLTAGE PHASE KW PART NUMBER CONTACTOR
208 1 15 04540-121-68-45 05945-111-68-37
230 1 15 04540-121-68-46 05945-111-68-37
208 3 15 04540-121-68-45 05945-002-24-70
230 3 15 04540-121-68-46 05945-002-24-70
460 3 15 04540-121-68-47 05945-002-24-70
208 1 18 04540-121-79-30 05945-111-68-37
230 1 18 04540-121-79-31 05945-111-68-37
208 3 18 04540-121-79-30 05945-002-24-70
230 3 18 04540-121-79-31 05945-002-24-70
460 3 18 04540-121-79-32 05945-002-24-70
SERVICE NOTES: When replacing wash heaters, it is highly recommended to change the gasket as well. Once installed,
gaskets become compressed and are subject to extreme temperature changes. Replacing the gasket with the heater
might prevent future leaks.
The nuts used to secure the heater to the casting should be torqued to 16 in-lbs. After tightening, the unit should be allowed
to heat up and operate normally for approximately 30 minutes. Secure power to the machine and check the nuts once more
to verify they are torqued to 16 in-lbs.
WASH HEATERS