07610-004-91-86-D
5
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
On three-phase machines, imbalanced wild leg goes to L3.
Also see the Motor Rotation section.
NOTICE
Local codes may require more stringent protection than what is displayed here and on the data plate. Always verify with
your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes.
Numbers in this manual are for reference and may change without notice.
Volts Phase Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load MCA MOP
208 1 60 Hz 5.0 A 19.7 A 50.6 A 75.3 A 76.6 A 80.0 A
230 1 60 Hz 5.0 A 21.8 A 55.9 A 82.7 A 84.0 A 90.0 A
208 3 60 Hz 5.0 A 11.4 A 29.2 A 45.6 A 46.9 A 50.0 A
230 3 60 Hz 5.0 A 12.6 A 32.3 A 49.9 A 51.2 A 55.0 A