INSTRUCTIONS
INSTALLATION
Electrical and grounding conductors must comply with the applicable portions of the
National Electric Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Refer to data plate for machine operating requirements, machine voltage, total
amperage, and serial number. Data plate is located on right side of the machine.
1. Open control box by using a phillips screwdriver to remove four screws on front
cover.
2. Install 3/4” conduit into pre-punched holes in back of control box.
3. Route incoming-power wires, and connect to power block and grounding lug.
4. Install service wires (L3 for 3-Phase) to appropriate terminals as they are marked
on the terminal block.
5. Install grounding wire into the lug provided.
6. Tighten connections.
“DE-OX” or similar anti-oxidation agent should be used on all power
connections.
CAUTION! Improperly connecting external devices can cause damage to the
machine and/or electrical infrastructure! Click here for a wiring guide.
On 460 V, 3-Phase machines only, verify correct pump motor rotation before
operating the machine. Failure to do so can result in damage to the machine and
components and may void the warranty.
1. Follow Filling the Wash Tub section.
2. Remove left side panel of the machine.
3. Locate wash pump motor and identify arrow decal which shows correct motor
rotation (if no decal is present, correct rotation is away from pump volute).
4. Push delime button on display.
5. Observe rotation of motor fan and quickly push delime button again.
6. If rotation is incorrect, disconnect electrical power and reverse L1 and L2
connections at terminal block shown in section above.
ELECTRICAL POWER
CONNECTIONS
NOTICE
If necessary, see
Heaters page for
phase conversion kit.
Disconnect electrical
power supplies and
lockout/tagout in
accordance with
appropriate procedures
and codes at the
disconnect switch.
MOTOR ROTATION
i
CAUTION! On 460 V,
3-Phase machines only,
verify correct pump
motor rotation before
operating machine!
!
CAUTION
Imbalanced wild
leg goes to L3.
NOTICE
Pump Volute
Motor Fan
L1
L2
WILD
L3
LEG
3Φ