OBSERVATION POSSIBLE CAUSE REMEDY
Wash
temperature
not at required
temperature
range.
1. Water level low.
2. RTD setpoint too slow.
3. Defective RTD.
4. Wash heater defective.
5. Defective heater contactor R1.
1. Check water level. If low, run new ll cycle.
2. Check fault screen. Adjust wash temperature setpoint
3. Replace.
4. Replace heater element.
5. Replace.
Rinse water
not at
required
temperature
range.
1. Incoming rinse water does not
meet minimum criteria indicated on
machine data plate.
2. RTD is defective.
3. Rinse heaters damaged.
4. Setpoint screens set low.
1. Adjust as required.
2. Replace if necessary.
3. Check amperages. Replace if necessary.
4. Adjust rinse tank setpoint.
Machine
doesn’t drain
when POWER
button is
pressed.
1. Drain clogged.
2. Defective drain valve.
1. Remove obstruction.
2. Replace.
No indication of
pressure.
1. Water turned off.
2. Pressure gauge failure.
1. Turn water on.
2. Replace pressure gauge.
TROUBLESHOOTING
TROUBLESHOOTING
WARNING! Inspection, testing, and repair of electrical equipment should only be performed by qualied service
personnel. Certain procedures in this section require electrical tests or measurements while power is applied
to the machine. Exercise extreme caution at all times. If test points are not easily accessible, disconnect
power, attach test equipment, and reapply power to test. When replacing electrical parts, disconnect power at
source circuit breaker.
!
WARNING