SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
CHEMICAL DISPENSING EQUIPMENT
8
TO PREPARE PUMPS FOR OPERATION
Delta Glasswashers are supplied with detergent, rinse additive, and sanitizer dispensing chemical feeder pumps. Locate the
open ends of the chemical tubes with the tube stiffeners and place each one in the appropriate container.
A. Red Tubing = Detergent
B. Blue Tubing = Rinse Aid
C. White Tubing = Sanitizer
PRIMING CHEMICAL FEEDER PUMPS
Chemical feeder pumps need priming when the machine is first installed, when chemicals are replenished, or if for some rea-
son the chemical lines have been removed and air is allowed to enter.
1. Verify that the proper chemical tube stiffener inlet is in the proper container.
2. Use the push buttons on the right side of control box to prime each pump.
3. To prime the pumps, hold the push buttons until chemical can be observed exiting the pump.
4. Detergent is dispensed as required during the wash tank fill. The amount of detergent may need to be increased or
decreased depending on water quality and type of detergent. It is adjusted by turning the potentiometer on the speed control
board clockwise to increase, counter-clockwise to decrease.
5. Rinse additive is dispensed proportionally into the final rinse water line. The amount of rinse aid may need to be adjusted
depending on water hardness and results. It is adjusted by turning the potentiometer on the speed control board clockwise to
increase, counter-clockwise to decrease.
6. Sanitizer (either chlorine or iodine) is dispensed proportionally into the final rinse water line. The amount of sanitizer may
need to be adjusted depending on concentration and the type of sanitizer used. It is adjusted by turning the potentiometer on
the speed control board clockwise to increase, counter-clockwise to decrease.
7. WARNING: Some of the chemicals used in dishwashing may cause chemical burns if they come in contact with your skin.
Wear appropriate protective gear when handling these chemicals. If you do come in contact with these chemicals, flush the
area with fresh water.
This equipment is not recommended for use with deionized water or other aggressive fluids. Use of deionized water
or other aggressive fluids will result in corrosion and failure of materials and components. Use of deionized water or
other aggressive fluids will void the manufacturer's warranty.
Delta 115/Delta 1200 Technical Manual 07610-003-62-15-M
Issued: 10-27-08 Revised: 11-19-2015