07610-002-10-23-T
10
PRESSURE
REGULATOR
SHOCK ABSORBER
DRAIN LINE
The manufacturer has an optional water pressure regulator to accommodate areas
where water pressure uctuates or is higher than the recommended pressure. Take
care not to confuse static pressure with ow pressure: static pressure is line pressure in
a “no ow” condition (all valves and services are closed); ow pressure is the pressure
in the ll line when the valve is opened during the cycle.
See the Plumbing Options page.
It is suggested that a shock absorber (not supplied) be installed on the incoming water
line. This prevents water hammer (hydraulic shock)—induced by the solenoid valve
as it operates—from causing damage to the equipment.
See the Plumbing Options page.
The drains for the models covered in this manual are gravity discharge drains. All piping
to the machine must be 2" NPT and must not be reduced. There must also be an air-gap
between the machine drain line and the oor sink or drain. If a grease trap is required by
code, it should have a ow capacity of 5 GPM.
After installing the incoming ll line and drain line, slowly turn on the water supply to
the machine. Check for any leaks and repair as required. All leaks must be
repaired before operating the machine.
Take care not to confuse
static pressure with
ow pressure!
PLUMBING CHECK
INSTRUCTIONS
INSTALLATION