Jackson Conserver XL2 handleiding
Handleiding
Je bekijkt pagina 14 van 64

07610-002-10-23-T
7
Model Designation: XL2
Operating Capacity:
Racks per Hour 74
Dishes per Hour 1850
Glasses per Hour 2664
Tank Capacity:
Wash Tank (gallons) 3.1
Wash Tank (liters) 11.7
Wash Pump Capacity:
GPM 61
LPM 231
Electrical Loads (as applicable):
Wash Motor HP 1.0
Operating Times (seconds):
Wash 53
Rinse 14
Dwell 20
Total Cycle Time 87
Always refer to the machine data plate for specic electrical and water requirements.
The material provided in this manual is for reference only and is subject to change without notice.
Water Temperatures (°F):
Wash Temperature (minimum/recommended) 120/140
Rinse Temperature (minimum/recommended) 120/140
Inlet Temperature (minimum/recommended) 120/140
Other Water Requirements:
Water Flow Pressure (PSI) 20 +/- 5
GPH 91.26
Water Line Size (NPT) 3/4”
Drain Line Size (NPT) 2”
Minimum Chlorine Required (PPM) 50
OPERATING CAPACITIES
SPECIFICATIONS
NOTICE
Bekijk gratis de handleiding van Jackson Conserver XL2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Jackson |
| Model | Conserver XL2 |
| Categorie | Vaatwasser |
| Taal | Nederlands |
| Grootte | 9470 MB |







