7
Model Designation: XL2
Operating Capacity:
Racks per Hour 74
Dishes per Hour 1850
Glasses per Hour 2664
Tank Capacity:
Wash Tank (gallons) 3.1
Wash Tank (liters) 11.7
Wash Pump Capacity:
GPM 61
LPM 231
Electrical Loads (as applicable):
Wash Motor HP 1.0
Operating Times (seconds):
Wash 53
Rinse 14
Dwell 20
Total Cycle Time 87
Always refer to the machine data plate for specic electrical and water requirements.
The material provided in this manual is for reference only and is subject to change without notice.
Water Temperatures (°F):
Wash Temperature (minimum/recommended) 120/140
Rinse Temperature (minimum/recommended) 120/140
Inlet Temperature (minimum/recommended) 120/140
Other Water Requirements:
Water Flow Pressure (PSI) 20 +/- 5
GPH 91.26
Water Line Size (NPT) 3/4”
Drain Line Size (NPT) 2”
Minimum Chlorine Required (PPM) 50
OPERATING CAPACITIES
SPECIFICATIONS