5.1 Technical specifications
Ethernet interface: 10/100 MBit, twisted pair
Microcontroller: Freescale MCF5235, 150 MHz
RAM / Flash: 8 MByte SDRAM / 4 MByte
CAN controller: internal and 1x Philips SJA1000T
CAN transceiver: Texas Instruments SN65HVD251P
Max. number of CAN bus nodes: 120
CAN bus termination resistor: none
CAN propagation delay: with galvanic isolation typically 32 ns
CAN baudrates: 10 kBaud to 1 MBaud
Max. CAN message rate 21000 messages/s (continuous)
(with VCI, receive direction): 21000 messages /s (burst)
Max. CAN- message rate 7200 messages /s (continuous)
(with VCI, transmit direction):
Power supply: +9 V to +32 V DC
Power consumption (normal): typically 110 mA (at 24 V input voltage)
maximum 250 mA (at 24 V input voltage)
Housing material: Polyamide
Dimensions (L x B x H) in mm: 114.5 x 99 x 22.5
Weight: approx. 300 g
Protection class: IP30
Operating temperature range: -20 °C to +70 °C
Storage temperature range: -40 °C to +85 °C
Relative humidity: 10 to 95 %, non-condensing
Galvanic isolation: 500 V AC for 1 min
Environmental directive: RoHS, WEEE, directive (2002/95/EC)