TROUBLESHOOTING
SYMPTOM CAUSE(S) CORRECTIVE ACTION
1. Filter Pump will not start 1a. Defective thermostat Replace thermostat
when temp. is below 32˚F. 1b. Defective relay Replace relay
1c. Faulty wiring Check wiring
1d. Power outage Install stand-by power
2. Time Switch will not keep time 2a. Frequent power outages Reset dial
-dial is turning. 2b. Wrong voltage/cycle Change clock motor
2c. Loose clock motor connections Check connections
3. Time Switch Dial stops at ON 3a. Loose tripper Check/change tripper
or OFF tripper. 3b. Bent dial Check/change mechanism
3c. Defective motor Change clock motor
4. Load is ON at all times - dial is 4a. Welded contacts Change mechanism
turning. 4b. Two ON-trippers on dial Change tripper
4c. Defective mechanism Change mechanism