9
IMPORTANT
During the installation, the main Regulations that apply:
Health and Safety at Work Act (HSWA)
Workplace (Health, Safety and Welfare) Regulations
Manual Handling Operations Regulations
Regulatory Reform (Fire Safety) Order
Electricity At Work Regulations
Control of Substances Hazardous to Health (COSHH)
Regulations
The system must not be positioned near flammable
substances. This can lead to a fire hazard.
The indoor unit must always be positioned upright.
Ensure that the wall on which the indoor unit is mounted
is strong enough to support the system. Additional
reinforcement is required if the system is installed on
plasterboard stud walls.
The CH system must be filled and ventilated.
The water pressure in the CH system must be at least 1.0
to 1.5 bar when cold. Do not use the CH system if it is not
full and vented.
Ensure that the outdoor unit is placed on a foundation that
is stable and level enough to prevent it from tipping over.
Ensure that condensed water can be drained.
Check whether the correct circuit breaker (B16) has been
fitted to the electrical consumer unit. If the circuit breaker
is too high, unsuitable or missing it can lead to short-
circuiting or fire.
Check whether the electrical supply circuit(s) to which
the installation will be connected is/are suitable for the
required capacity.
Ensure that a three-pole isolator switch (see §8.7.3 and
§8.8.1) is placed near the outdoor unit, it must be IPX rated
and designed to carry the required electrical loading.
The extra fittings specified within these installation
instructions (filter, non-return valve and wiring etc.)
must be supplied and fitted by the installer. Damages and
consequences resulting from not applying the specified
fittings are not covered by the Intergas warranty and will be
the responsibility of the installer/user.
Before installing any type of low temperature heating
system it is essential a full room by room heat loss
calculation is completed of the property, this should be
fully explained to the home owner, especially regarding
the dierent operational aspects, temperature of the
emitters, duration of operation, electricity usage etc. It is
recommended that the level of thermal insulation for the
property walls, floor and roof are increased (where possible)
to the maximum to help lower the U-values (The lower the
U-value, the slower the heat escapes from the property).