61
Enter the service code to con�nue
15
Cancel Confirm
1. Select the service menu.
2. Enter service code 15.
3. Click on ‘confirm’.
4. The menu will now be available.
The installation wizard has been specifically designed to assist in
commissioning and configuring the parameters.
The wizard will start on its own when you connect to the Wi-Fi control
screen for the first time.
1. Connect to the Wi-Fi control screen.
2. Enter the service code.
3. Follow the installation wizard instructions.
NOTES
The installation wizard takes several minutes
and can be accessed at any time via the service
menu.
11.2.2 Installation wizard
11.2 Service menu (specifically for the installer)
11.2.1 Access to the service menu
The following tool functions can be used to commission other system
elements or if work or maintenance is required on the system.
There is a ‘start‘ and ‘stop‘ button for all programs.
Pump venting
During this program, the pump will operate slowly and stop at brief
intervals, so that any air within the system can easily be vented.
This process will repeat itself until the system detects a stable flow.
During this process, please ensure that the manual air vents on top
of the indoor unit, the boiler and the radiators are correctly vented,
(§9.3 - point 2)
Activating the system pump
During this program, the pump will operate continuously. Use the
arrows to set the desired flow rate (l/min).
Manual defrosting
During this program, the heat pump evaporator will be defrosted.
Heat pump service mode (minimum)
During this program, the pump will operate at minimum output.
Heat pump service mode (maximum)
During this program, the pump will operate at maximum output.
Boiler service mode
During this program, the boiler will be activated.
Pumping out refrigerant
The pump draining function can be used to commission the
system, such as by emptying the meter set, for maintenance
work or decommissioning the system. During this process, the
refrigerant will be moved back into the outdoor unit, §8.6.8
11.2.3 Tools