Intergas Xtend Split handleiding

88 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 58 van 88
58
11 SETTINGS AND ADJUSTMENTS
Various (parameter) settings on the Wi-Fi control screen are used
to influence how the system functions.
Some of these settings can be changed by the end user as well
as the installer. Other settings can only be changed within the
service menu using the service code 15; see §11.2.1.
The following menus on the Wi-Fi control screen are important
for this:
Settings
Service (specifically for the installer)
11.1 Settings (Wi-Fi control screen)
11.1.1 Discription day programs
The system is equipped with an option to operate in Silent mode
(e.g. during the night). This mode can be activated/deactived using
the parameter P172. When this mode is activated, the speed (rpm) of
both the compressor and the fan is adjusted to reduce the noise level
of the outdoor unit. Set the parameter P167 to the desired capacity
reduction (compressor reduction percentage).
By following the steps below, 2 time periods (1 to 2 and 3 to 4) can be
programmed on the control screen for when Silent mode is active.
This mode is automatically deactivated when the outdoor
temperature is too low. This is done to ensure that the system
will still operate at the capacity required to heat the residence or
avoid an excessive drop in temperature as a result of Silent mode
operation. The minimum external temperature before Silent mode is
deactivated can be set using the parameter P171.
Silent Mode
Heat pump blockage
Silent Mode
Use this function only when there is a
noise issue (i.e. night time operation).
Observe local noise level regulations.
The Silent Mode can lead to less comfort
and/or higher energy costs.

Bekijk gratis de handleiding van Intergas Xtend Split, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkIntergas
ModelXtend Split
CategorieNiet gecategoriseerd
TaalNederlands
Grootte11570 MB