Intergas Xclusive 36 handleiding
Handleiding
Je bekijkt pagina 58 van 92

58
9.1.6 Info menu
The info menu is accessible by touching the Service symbol
from the service menu and holding it for 2 seconds.
(Note if you are not in the service menu you will need to touch
the service symbol and hold it for 2 x 2 seconds).
Via the info menu certain boiler operational statistics can be
viewed.
The following symbols will illuminate:
► The minus symbol
► The plus symbol
Respectively the right and le display will display the relevant
infocode and its corresponding value.
By tapping the plus symbol and the minus symbol the
following characteristics are displayed in succession:
Le display Right display
► Ionisation current in µA
► Domestic hot water flow in litres/minute
► Boiler output in kW
► Pump RPM in %
► Last fault code
► Current PCB Firmware version
► Current Firmware version DSP processor
► Temperature sensor S0 (Heat exchanger)
► Temperature sensor S1 (Htg flow)
► Temperature sensor S2 (not present)
► Temperature sensor S3 (DHW)
► Temperature sensor S4 (not present)
► Temperature sensor S5 (Flue gas)
► Temperature sensor S6 (Outdoor sensor option)
► Temperature sensor S7 (Cylinder sensor option)
Info menu
Ionisation current
Info menu
DHW flow
Info menu
Boiler output
Info menu
Pump RPM
Info menu
Last fault code
Info menu
Current PCB firmware version
Info menu
Current Firmware version DSP processor
Info menu
Temperature sensor S0 (Heat exchanger)
Info menu
Temperature sensor S1 (Htg flow)
Info menu
Temperature sensor S3 (DHW)
Info menu
Temperature sensor S5 (Flue gas)