8.2.1 Filling and venting the central heating system
8.2 Boiler preparation
8.1 Using the control panel
8 OPERATION
2sec
Central heating pressure is too low.
Gently touch and release the white power LED symbol
Gently touch and hold the white power LED symbol for 2 seconds
Connect the power cable to a 3 amp fused spur supplied via
a type "A" RCD.
Switch on the power supply to the boiler, A 22 may
momentary appear on the right display; this means that the
internal sensors are being checked. The firmware version
will be momentary shown on the le display.
The boiler enters standby power o mode, characterised by
a line – on the right display and the central heating system
pressure on the le display.
When the central heating pressure is
lower than 0.5 bar, this will be indicated
by a flashing display (if the boiler is in
central heating demand).
If the central heating pressure is below
0.2 bar then the demand will no longer
be met.
WARNING
When an additive is added to the
central heating water, this must be
suitable for the materials used in the
boiler,such as copper, brass, steel,
stainlesssteel, plastic and rubber.
Intergas recommend products
manufactured from :
Fernox Tel 0330 100 7750
ADEY Innovations Tel 01242 546 777
Altecnic Calei Group Tel 01785 218 200
Power on / power o mode.