Intergas Xclusive 30 handleiding

92 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 75 van 92
75
10.2.7 Burner resonates
10.3 Notifications
Possible causes Analysis Solution
Gas inlet pressure lower than 20mbar
or sometimes lower.
Yes
No
The Gas meter governor may be defective. In this case, contact
the energy company 0800 111999.
There is recirculation of flue gases.
Yes
No
Check the flue and air supply ducts and seals.
Gas-air control is not correctly
adjusted.
Yes
No
Check the adjustment; see §9.9 and §9.10.
Burner seal is defective. Yes
No
Replace the burner seal.
Burner is defective. Yes
Replace the burner.
In addition to error codes, the burner control can also show notifications on the display. Notifications
are displayed if an anomaly occurs somewhere in the system that does not aect the vital functioning
of the system. Notifications disappear if the system can fix the abnormality. Intergas Heating should
be consulted if a notification returns repeatedly.
The following notifications are distinguished:
Notification Description Possible cause / solution
N030
DHW demand is blocked.
Check if parameter P001 is set correctly.
Check wiring of domestic hot water sensor S3 for damage and
ensure its connected correctly.
Ensure the DHW sensor resistance values are correct.
Check for the correct operation of domestic hot water sensor S3.
Replace domestic hot water sensor S3.
N152
Power reduction due to flue gas
sensor faulty.
Check whether flue gas sensor S5 is present and install it if
necessary.
Check whether it has been mounted correctly.
Check the wiring for break / short circuit.
Replace flue gas sensor S5.
N202
Burner switched o due to flue
gas temperature limitation.
Flue gas temperature higher as to be expected. Check the fins
of the heat exchanger for wear. Replace the heat exchanger if
necessary.
N245
Fan speed adapted to CAC
protection.
Backflow of flue gasses detected. Fan on low speed to prevent
recirculation of flue gasses. Check the flue gas non-return valve.