Aer filling the heating and hot water systems correctly, the
boiler can be commissioned by following the below procedure
for this:
Switch on the boiler by touching just above the power LED
and holding this for 2 seconds.
Adjust the pump setting depending on the set maximum
capacity and the heating circuit resistance.
To adjust the pump capacity of the boiler; see §9.6.
Adjust the temperature on the room thermostat to higher
than the actual room temperature so the boiler creates a
heating demand (Timer must be set to on).
Symbols
and light up.
Heat up the system.
Check whether the set central heating output is suicient
to achieve the room target temperature. If necessary, the
maximum central heating output can be adjusted; see §9.3
(parameter P010) and §9.5.
Check whether the set minimum and maximum values of
the pump output have been adjusted correctly; see §9.3.
Switch o the boiler by touching just above the power LED
and holding this for 2 seconds.
Vent the system again once cool and top-up the pressure if
required (see §8.2.1).
Now switch on the boiler again by touching just above the
power LED and holding this for 2 seconds.
Check the heating and the domestic hot water facility for
correct operation.
Instruct the end user about filling and venting and the
operation of the heating and the domestic hot water.
Hand the installation instructions and warranty registration
card to the customer / end user.
The heating system must be chemically flushed and treated
to BS7593:2019 as per our "Terms & conditions" failure to
comply will invalidate the warranty supplied with this
product, a system filter should be installed on the return
pipework.
8.3 Commissioning procedure
Switch on boiler
2sec
Switch o boiler
2sec
Comments
The boiler has microprocessor control technology which
ignites the burner and continuously monitors the flame,
modulates the fan and pump with each demand for central
heating output.
The modulating pump operates during a demand for
heating, it has an overrun facility preset in parameter P033
and it is advised not to adjust this setting.
The pump automatically runs once every 24 hours for 10
seconds to prevent it becoming stuck during the summer
months, this operation takes place 24 hours aer the last
heat demand.
Please note the pump does not operate during domestic
hot water operation.