Intergas Heating Ltd 36
Concealed Flue Joints:
Acceptable Installations:
Telescopic Flue & terminal: The telescopic overlap in Intergas horizontal flue is not considered as a flue joint. The flue
section must be adjusted to the correct length then the telescopic joint must be secured and sealed with the screw and tape
provided in line with manufacturers instructions. It is acceptable for this secured, sealed overlapping connection to be sited
within the building fabric.
Non- acceptable Installations
Flue Extensions & Elbows: Flue joints between flue extensions & elbows must not be sited within the building fabric. Where
necessary flue extensions should be cut to suit to avoid this.
Flue Integrity:
The flue should be inspected under its annual service and at the initial commissioning of the appliance to confirm:
• All joints in the flue system are sound and correctly assembled according to manufacturers instructions.
• The flue is continuous without any breaks.
• All flue joints should be visible for visual inspection.
• Checked by means of sampling the air intake at the flue air intake sample point with a calibrated flue gas analyser.
• All voids containing concealed flues should have inspection hatch measuring no less 300mm square.
(Ref TB 008Ed3)