Intergas Heating Ltd 33
7.6.3 Flue pipe and air supply
For connecting the boiler to a concentric flue system a special concentric flue
adapter has to be used. An adapter for connecting to a 60/100 flue system can
be ordered at Intergas Heating Ltd. See chapter 5.2, Flues.
Note
Only use approved Intergas flue products with this boiler, which can be sourced
from the supplier of your boiler or Intergas stocklist.
Terminal Position
Min.
distance
A
Directly below an open able window or other opening
e.g. air brick
300 mm
B
Below gutters, soil pipes or drain pipes can be
reduced to 25mm, as long as the flue terminal is
extended to clear any overhang. External flue joints
must be sealed with suitable silicon seal.
25 mm
C
Below eaves
200 mm
D
Below balconies or car front roofs
200 mm
E
From vertical drain pipes and soil pip
25 mm
F
From internal or external corners
300 mm
G
Above ground, roof or balcony level, Terminal guards
must be fitted if less than 2 metres from the ground.
300 mm
H
From a surface facing a terminal
600 mm
I
From a terminal discharging towards another terminal
1200 mm
J
From an opening in a car port (e.g. door, window) into
a dwelling
1200 mm
K
Vertically from a terminal on the same wall
1500 mm
L
Horizontally from a terminal on the same wall
300 mm
M
Above an opening, air brick, opening windows, etc.
300 mm
N
Horizontally to an opening, air brick, opening
windows, etc.
300 mm
P
Above roof level (to base of terminal)
300 mm
Q
From adjacent wall to flue
300 mm
R
From an adjacent opening window
1000 mm
S
From another roof terminal
600 mm
-
From an external boundary. Note: if the terminal is
facing a boundary it is recommended that an anti-
plume kit be fitted.
600 mm
Terminals adjacent to windows or openings on
pitched and flat roofs:
T
The flue should not penetrate this area.
T1
2000 mm
T2
600 mm
Note
Intergas cannot be held responsible for atmospheric conditions when siting flue
terminals
CAUTION
Once the flue has been installed and the appliance
commissioned, installer should observe the plume direction.
Particular attention should be drawn to plume vapour re-
entering the boiler via the air intake. If this occurs, it is highly
possible the flue is fitted within a negative pressure area and
therefore a plume management kit (PMK) must be fitted.