Intergas Heating Ltd 24
7. CONNECTIONS
7.1 Connect the CH system
1. Flush the CH system thoroughly.
2. Fit the flow (B) and return (A) pipes together with the shut-off valves to
the boiler.
All pipes must be mounted tension-free in order to avoid ticking of the
pipes. Existing connections inside the boiler must not be twisted in
order to avoid leakages.
The CH system should be provided with:-
A filling/draining tap in the return pipe immediately below the
appliance.
A drain tap at the lowest point(s) of the installation.
NOTE
The boiler is equipped with an internal pressure relieve
valve
A check valve, if pipes run upwards at a short distance from the
appliance. This avoids the occurrence of thermosiphon effect during
DHW operation mode.