2. SAFETY REGULATIONS
The manufacturer Intergas Heating Ltd accepts no liability whatsoever for damage or injury caused by failure to adhere (strictly)
to the safety regulations and instructions, or carelessness during installation of the Intergas Rapid High Efficiency wall mounted
gas fired boiler and any associated accessories.
2.1 General
It is law that all gas appliances are installed and serviced by a Gas Safe
registered competent engineer if in any doubt please check with Gas Safe (0800
408 5500) and in accordance with the following recommendations:
Current Gas Safety (Installation and Use) Regulations
All current building regulations
Building Standards (Scotland) Consolidated
This appliance must be installed in accordance with the Gas (Safety and
Use) Regulations, current Building Regulations, Building Standards
(Scotland), I.S.813 Installation of Gas Appliances (Ireland), IEE Wiring
Regulations (BS 7671), Health and Safety Document No. 635 (Electricity at
Work Regulations) and Local Water Authority Bye Laws
UK Water Regulations and Bye Laws
Health & Safety
Safety precautions If you smell gas
A gas leak could potentially cause an explosion. If you smell gas, observe the
following
rules.
Prevent flames or sparks:
Do not smoke, use a lighter or strike matches.
Do not operate any electrical switches or unplug any equipment.
Do not use the telephone or ring doorbells.
Turn off the gas at the meter or regulator.
Open windows and doors.
Warn your neighbours and leave the building.
Prevent anyone from entering the building.
Call the National Gas Emergency Service on 0800 111 999.
L.P.G. boilers: Call the suppliers number on the side of the gas tank
2.2 The Installation
The installation must comply with the following British Standards codes of
practice:
BS 5440: Flues and Ventilation for gas appliances of rated input not exceeding 70kW (Part 1 Flues)
BS 5440: Flues and Ventilation for gas appliances of rated input not exceeding 70kW (Part 2 Air Supply)
BS 5546: 2000 Installation of gas hot water supplies for domestic purposes.
BS 5549: 1990 Forced circulation hot water systems
BS 6700: 1997 Design, Installation, testing and maintenance of services supplying hot water
BS 6798: 2000 Specification for installation of gas fired hot water boilers of rated input not exceeding 70kW
BS 6891: 1998 Installation of low pressure gas pipe-work installations up to 35mm (RI)
BS 7593: 1992 Code of practice for treatment of water in heating systems
BS 7671: 2001 Requirements for electrical installations, IEE Wiring regulations
Reference should also be made to:
Guide to condensing boiler installation assessment procedures for dwellings