Infiniton CSTCH24A2 handleiding

216 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 104 van 216
inniton.es104
English
Installation
All wiring must comply with local and national electrical codes and must be installed by a licensed elec-
trician.
Gas Leak Checks
There are two different methods for checking for gas leaks.
Soap and water method
Using a soft brush, apply soapy water or liquid detergent to all pipe connection points of the indoor and
outdoor unit. The presence of bubbles indicates a leak.
Leak detector method
If using a leak detector, refer to the instruction manual of the device for corresponding operating ins-
tructions.
After performing the gas leak check
After conrming that all pipe connection points are NOT leaking, replace the valve cover on the outdoor
unit.
Electrical and gas leakage testing
Before the function test
Only perform the function test after the following steps have been completed:
Electrical safety checks -Conrm that the unit’s electrical system is safe and functioning properly.
Gas Leak Check - Check all are nut connections and conrm that the system does not leak.
Conrm that the gas and liquid valves (high and low pressure) are fully open.
Electrical safety checks
After installation, conrm that all electrical wiring was installed in accordance with local and national
regulations and in accordance with the installation manual.
Before the function test
Check the earthing work
Measure the grounding resistance by visual detection and with the grounding resistance tester. The
grounding resistance must be less than 0.1 Ω.
Note: This may not be necessary for some locations in North America.
During the function test
Check for Electrical Leakage
During the Run Test, use an electrical probe and a multimeter to perform a complete electrical leakage
test.
If electrical leakage is detected, turn off the unit immediately and call a licensed electrician to nd and
resolve the cause of the leakage..
WARNING! RISK OF ELECTRIC SHOCK
A: Low pressure shut-off valve
B: High pressure shut-off valve
C and D: Indoor unit are nuts
A
B
C
D
Outdoor unit control point
Indoor unit control point

Bekijk gratis de handleiding van Infiniton CSTCH24A2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkInfiniton
ModelCSTCH24A2
CategorieNiet gecategoriseerd
TaalNederlands
Grootte32676 MB