Local air conditioner/User Manual
25 / EN
Take special care that drained
refrigerant will not float back into
the building.
Evacuate the refrigerant circuit.
Purge the refrigerant circuit
with nitrogen for 5 min.
Evacuate again.
Fill with nitrogen up to
atmospheric pressure.
Put a label on the equipment
that the refrigerant is removed.
e) Disposal
Ensure sufficient ventilation at
the working place.
Remove the refrigerant. If
the recovery is not required
by national regulations, drain
the refrigerant to the outside.
Take care that the drained
refrigerant will not cause any
danger. In doubt, one person
should guard the outlet. Take
special care that drained
refrigerant will not float back
into the building.
Evacuate the refrigerant circuit.
Purge the refrigerant circuit
with nitrogen for 5 min.
Evacuate again.
Cut out the compressor and
drain the oil.
Transportation, marking and
storage for units that employ
flammable refrigerants
Transport of equipment
containing flammable
refrigerants
Attention is drawn to the fact
that additional transportation
regulations may exist
with respect to equipment
containing flammable gas. The
maximum number of pieces of
equipment or the configuration
of the equipment, permitted to
be transported together will be
determined by the applicable
transport regulations.
Marking of equipment using
signs
Signs for similar appliances
used in a work area generally
1 Safety awareness