Installation Instructions (Continued)
Minimum Ventilation Clearances
Air Intake:
An air intake should be provided somewhere in the cabinet run to
allow free air in. In this example, a plinth vent is shown underneath
the refrigerator .
A cutout should be made in the plinth below the freezer
and this finished neatly using the air vent grille supplied.
Alternatively, a thin section of the plinth can be
removed to allow air into the unit
(recommended 600mm × 10mm)
Rear Clearance:
A minimum 30mm gap must be maintained
between the refrigerator and the rear wall
for proper air circulation over the condenser.
Recommended rear vent opening:
500mm × 35mm.
Top Ventilation:
The cabinet’s top must allow airflow
to vent into the room.
Recommended minimum opening:
500mm × 30mm.
If no free airflow is available into
the room, a plinth vent or another form
of ventilation must be installed.