CONVECTION OVEN – ELECTRICAL CONNECTION
Imperial ranges with CONVECTION OVEN requires a 120 volt supply to operate the ignition systems and
circulating fan. The supply cord provided on the appliance is equipped with a three prong (grounding) plug for
protection against shock hazard. The electrical service in the building must be equipped with a properly grounded
three prong receptacle, in accordance with local codes, or in the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.2, as applicable. Do not cut or remove the
grounding prong from this plug. Wiring diagram is located on the backside of the side control panel. Disconnect
power supply before cleaning or servicing.
GAS CONNECTION
NOTE: The gas supply (service) line must be the same size or greater than the inlet line of the appliance. Contact
manufacturer for inlet size of unit. Sealant on all pipe joints must be resistive to LP gas.
MANUAL SHUT-OFF VALVE
This installer supplied valve must be installed in the gas service line ahead of the appliance and regulator in
the gas stream and in a position where it can be reached quickly in the event of an emergency.
PRESSURE REGULATOR
All commercial cooking equipment must have a pressure regulator on the incoming service line for safe
and efficient operation, since service pressure may fluctuate with local demand. The manual shut-off valve is
normal supplied by the installer.
Failure to install a pressure regulator will void the equipment warranty
The regulators supplied for Imperial ranges are adjusted at the factory for 5” WC (natural gas) or
10” WC (propane) depending on the customer’s ordering instructions.
Any adjustments to regulators must be made only by qualified service personnel with the proper test
equipment.
RIGID CONNECTIONS
Double-check any installer-supplied intake pipes visually and/or blow them out with compressed air to
clear any dirt particles, threading chips, or other foreign matter before installing a service line. Those particles will
clog orifices when gas pressure is applied.
All connections must be sealed with a joint compound suitable for LP gas and all connections must be
tested with a soapy water solution before lighting any pilots.
FELXIBLE COUPLINGS, CONNECTORS AND CASTERS
If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must use a
heavy-duty, AGA design-certified commercial flexible connector of at least ¾” NPT (with suitable stain reliefs).
The flexible connector must comply with the standard for Connectors for Movable Gas Appliances, ANSI Z21.69
(or latest edition) and a quick-disconnect device that complies with the standard for quick-disconnect devices for use
with Gas Fuel should comply with ANSI Z21.41(or latest edition). If disconnection of the restraint is necessary,
NOTE: This appliance is not capable of being operated in the event of power failure. No attempt should be
made to operate this appliance during a power failure.