Symptom Remedy
The device is not working, no
light, the fan is not running
Check the mains connection and main fuse.
No response to the DMX con‐
troller
1. Check the DMX connections and cables for proper
connection
2. Check the address settings and the DMX polarity.
3. Try using another DMX controller.
4. Check whether the DMX cables run near or parallel to
high-voltage cables that may cause damage or interfer‐
ence to a DMX interface circuit.
Unintended light eects Make sure that the DMX channel assignments of the
devices do not overlap, and that the DMX start address
of devices with independent control is always higher by
the number of channels that have been set for the DMX
mode on another device.
If the procedures recommended above do not succeed, please contact our Service Center. You
can nd the contact information at www.thomann.de.
Troubleshooting
68