SUHxxx Ultrasonic flow meter without display
14 © ifm electronic gmbh 11661449 / 01 07 / 2025
6.4 Use in hygienic areas according to 3-A
The sensor is suited for CIP (clean in place) when installed correctly.
Observe the application limits (temperature and material resistance) according to the data
sheet.
Not suitable for systems that have to meet the criteria of E9.2 / 63-04 of the 3-A standard
63-04.
For use according to 3-A, take note of the corresponding regulations for cleaning and
maintenance.
Ensure that the installation of the device in the system complies with 3-A guidelines.
Use only process adapters with 3-A certification and marked with the 3-A symbol ( Accessories at
www.ifm.com).
Secure clamp sensors with a suitable clamp.
Use self-draining installation.
To allow the medium to flow out of the process adapter, mount the device in the following installation
position:
Vertical installation in a rising pipe (A).
- or –
Horizontal position with a slight gradient so that the medium does not come to a standstill (B).
F
1
F
A B
Fig.5: Process connection according to 3-A. 1: Minimum gradient; F = flow direction
Type Minimum gradient
(DIN 32676 series A)
Type Minimum gradient
(DIN 32676 series C)
DN15 29° 1/2" ---
DN20 43° 3/4" 32°
DN 25 25° 1" 10°
DN40 49° 1 ½" 42°
DN 50 16° 2" 12°
DN65 23° 2 ½"
DN80 30° 3"