Encoder (SR) with CANopen interface RM900S RM901S RM902S RM903S
7
4 Intended use
The encoder (SR) is designed to record angular movement and process the measurement data for a
downstream evaluation system in plant equipment.
The encoder (SR) must be resistant to chemical substances with which it may come into contact and
must be tested (in accordance with ISO 19014-3).
A material is considered to be resistant if the properties do not change sufficiently upon contact with a
harmful substance to impair the material performance.
All materials in the encoder (SR) with potential media contact are listed in the technical data.
The encoder (SR) provides digital output signals based on the angular position of a moving part.
The measuring system is primarily used in plant equipment where reliable detection of the mechanical
position or speed of a moving part is required.
In accordance with IEC 61800-5-3, safe absolute position (SAP) and safe speed (SSV) are available.
Safe absolute position (SAP)
This function provides reliable information on the mechanical position of the angular movement
with specified tolerances via the CAN bus (→ Technical data).
Safe speed value (SSV)
This function provides reliable information on the speed of the angular movement with specified
tolerances via the CAN bus (→ Technical data).
The entire processing chain of the higher-level and overall safety function must meet the requirements
of the safety standard applied by the system integrator.
In safety applications, the encoder (SR) may only be used in conjunction with a controller that is
certified in accordance with the applicable safety standard.
The encoder (SR) is not able to independently bring about a safe state in the safety function.
Hazardous situations must be detected and evaluated by a higher-level fail-safe processing unit.
The system manufacturer must check whether the properties of the encoder (SR) meet its application-
specific safety requirements.
The responsibility for and decision regarding the use of the encoder (SR) lies with the system
manufacturer.
In case of faults within the encoder (SR) which lead to switchover into a defined safe state,
measures have to be taken which maintain the safe state when the complete control system
continues to be operated.
WARNING
Any improper use may lead to dangerous situations.
w Death, serious irreversible injuries and material damage are possible.
u Use the device only in accordance with the “Intended use”.