Je bekijkt pagina 15 van 61
Electronic manometer PG17xx
© ifm electronic gmbh 11601190 / 01 07 / 2025 15
6.3 Use in hygiene areas to 3-A and EHEDG
The sensor is suited for CIP (cleaning in process) and SIP (sterilisation in place) when installed
correctly.
Observe the application limits (temperature and material resistance) according to the data
sheet.
The gasket of the system interface must not be in contact with the sealing point of the sensor.
Use self-draining installation.
Leakage ports must be clearly visible and must be installed facing downwards for vertical pipes.
Observe the positioning of the sensor so that the medium can flow out of the mounting adapter: Do not
install the device in position 5.
1
2
3
4
5
Fig.3: Mounting position for use in hygienic areas in accordance with 3-A and EHEDG
6.3.1 Avoiding dead space
Make sure there is no dead space in the system where product residues, microorganisms or cleaning
agents can accumulate. The contacting parts of the sensing face must be easy to reach for cleaning and
must not be in a dead space.
For any structures in a tank, direct water jet cleaning must be possible. Cleaning of dead spaces must
be possible.
Adhere to the dimensions shown in the following figure to avoid dead spaces that cannot be cleaned
effectively: L < D for EHEDG and L 2D for 3-A.