Electronic manometer PG17xx
© ifm electronic gmbh 11601190 / 01 07 / 2025 5
2 Safety instructions
• The unit described is a subcomponent for integration into a system.
– The system architect is responsible for the safety of the system.
– The system architect undertakes to perform a risk assessment and to create documentation in ac-
cordance with legal and normative requirements to be provided to the operator and user of the sys-
tem. This documentation must contain all necessary information and safety instructions for the op-
erator, the user and, if applicable, for any service personnel authorised by the architect of the sys-
tem.
• Read this document before setting up the product and keep it during the entire service life.
• The product must be suitable for the corresponding applications and environmental conditions without
any restrictions.
• Only use the product for its intended purpose (
Intended use).
• Only use the product for permissible media (
Technical data).
• If the operating instructions or the technical data are not adhered to, personal injury and/or damage to
property may occur.
• The manufacturer assumes no liability or warranty for any consequences caused by tampering with the
product or incorrect use by the operator.
• Installation, electrical connection, set-up, operation and maintenance of the product must be carried
out by qualified personnel authorised by the machine operator.
• Protect units and cables against damage.
CAUTION
With high medium temperatures, parts of the device may heat up.
Risk of burns
Do not touch the device.
Protect the housing against contact with flammable substances and unintentional contact.
ATTENTION
Applications where steam is applied
Risk of mechanical damage of the sensor or the piping system due to steam surge.
Protect the sensor from excessive stress due to cavitation and steam surge.
Design the piping system according to the state of the art.
Do not install the sensor in the direct vicinity of fittings, pipe bends and the like in order to
prevent unnecessary maximisation of steam surges.
Preheat the system before the steam enters and remove liquid residues from the pipes, e.g.
by blowing out or other suitable measures.
The permissible temperatures of the sensor must not be exceeded
Data sheet.
2.1 Cybersecurity
Installation
The device is suitable for operation in a secure environment according to IEC 62443-1-1.
The device was designed for operation behind a firewall.
Carry out a risk assessment of the system according to IEC 62443-1-1.
Take measures to ensure physical security.