IFM PG1708 handleiding
Handleiding
Je bekijkt pagina 16 van 55

PG17xx Electronic manometer
16
The filter cover can be replaced with accessories 2...5 (Ò figure).
Information about available accessories at www.ifm.com
2
3
4
5
1
Fig.6: Replacing the filter cover of the ventilation diaphragm
1: Filter cover (as supplied)
2: Filter cover with integrated ventilation diaphragm
3: Closed filter cover
4: Filter cover with integrated ventilation diaphragm and tube fitting with vent tube that ends in a protected and dry area.
5: Set of accessories for high degree of soiling and high climate pollution:
Angle adapter with integrated ventilation diaphragm. Attachable:
• vent tube– or–
• plug-in element with integrated ventilation diaphragm– or–
• plug-in element with integrated ventilation diaphragm and vent tube
When using the closed filter cover (3), there is no pressure compensation of the measuring cell
any more. Potential measurement deviations caused by:
- fluctuations of the atmospheric pressure.
- pressure fluctuations inside the device in case of temperature fluctuations (Δ10K≤30mbar).
Procedure:
u Avoid soiling and moisture during the replacement.
u Clean the thread carefully and without residues.
u Do not damage the adhesive area of the sensor.
u Observe the orientation of the filter cover.
5.5.3 Orientation filter cover
u Install the device so that the filter cover is vertical and the condensate can drain off due to gravity.