Parameter Explanation
x.StA Starting point of the colour ranges:
[b.StA] = lower pressure limit of colour range 3 (base layer)
[m.StA] = lower pressure limit of colour range 2 (middle layer)
[t.StA] = lower pressure limit of colour range 1 (top layer)
x.End End point of the colour ranges:
[b.End] = upper pressure limit of colour range 3 (base layer)
[m.End] = upper pressure limit of colour range 2 (middle layer)
[t.End] = upper pressure limit of colour range 1 (top layer)
EF Change to the EF (extended functions) submenu
BACk Back to the next higher level (menu or last process value display)
Basic settings menu [CFG]:
[EF]
BACk
OU1
OU2
DIS
DIA
SIM
CFG
RES
----
PnPnPn
----
----
----
dAP.P
P-n
OFFECO
tcoF
coF.P
CGA.P
uni.T
bar / mbar *│psi
°C°F
uni.P
[CFG]
ECO.m
BACk
Main menu
* The pressure unit depends on the device type Ò Data sheet at ifm.com.
Parameter Explanation
uni.P Standard unit of measurement for pressure
uni.T Standard unit of measurement for temperature
dAP.P Damping constant in seconds for pressure (63 % rise time τ)
P-n Output polarity for the switching outputs
tcoF Parameter for teaching the correction factor for zero point calibration
coF.P Correction factor for zero point calibration, pressure
CGA.P Calibration factor in % for adapting the curve of measured values to the application
ECO.m Energy-saving mode [ECO] or energy-saving mode [OFF].