General information on IO-Link at io-link.ifm
Input Output Device Description (IODD) with all parameters, process data and detailed
descriptions of the device at documentation.ifm.com
IO-Link offers the following advantages:
• Interference-free transmission of all data and process values
• Parameter setting in the running process or presetting outside the application
• Parameters for identifying the connected devices in the system
• Additional parameters and diagnostic functions
• Automatic backup and restore of parameter sets in case of device replacement (data storage)
• Logging of parameter sets, process values and events
• Device description file (IODD - Input Output Device Description) for easy project planning
• Standardised electrical connection
• Remote maintenance
4.2 Zero point behaviour of the device display and outputs
Due to permissible device tolerances and temperature changes, the sensor can show a
deviation from the zero point when no pressure is applied. To prevent this, the device is
equipped with functions that keep the measured signal more stable at the process value 0.
Zero point behaviour of the device display and switching output:
5
4
1
0
0
5
+
+
-
2
3
Fig.1: Device display and switching output
1: Process value
2: Sensor output signal with hysteresis (green)
3: Ideal measurement signal (red)
4: System pressure
5:
Zero point stabilisation Ò Data sheet
The first process value that is shown on the device display and can be evaluated via the switching
output is determined by the zero point stabilisation.
The switching output cannot be configured within the zero point stabilisation.
The zero point stabilisation is specified in % of the span Ò Data sheet.