IFM MFH219 handleiding
Handleiding
Je bekijkt pagina 21 van 29

Pressure-resistant position sensor for hydraulic cylinders MFH2xx
© ifm electronic gmbh 11660562 / 00 06 / 2025 21
Save the parameter set on the device.
10.7.1.2 Read counter values
Select Parameters > Counter configuration.
Select SC-EnhCtr. SC1 and read the current value for counter SC1.
Select SC-EnhCtr. SC2 and read the current value for counter SC2.
10.7.1.3 Reset counters
Reset both counters:
Select Parameters > Counter configuration.
Execute the command: Reset SSC counter.
Both switching cycles counters are set to 0.
10.7.2 Operating hours counter
The operating hours since the first set-up are stored by the unit.
The operating hours counter is stored retentively every hour. If the operating voltage is interrupted, the
time since the last full hour will be lost.
The maximum counter reading of 2,000,000 h will be retained when it has been reached (no overflow).
The current value can be read via the IO-Link interface.
Select Diagnosis.
Select Operating hours and read value.
10.7.3 Power cycles
The device stores the switch-on operations since the first set-up.
The maximum counter reading of 2,000,000 will be retained when it has been reached (no overflow).
Select Diagnosis.
Select Power cycles and read value.
10.7.4 Internal temperature
The sensor measures the internal temperature.
The internal temperature may be higher than the actual temperature due to self-heating of the processor.
Due to the installation in a metallic cylinder, the temperature of the device is strongly coupled to the tem-
perature of the cylinder housing. If the cylinder becomes excessively hot due to wear or overload, this
trend can be detected with the device.
Select Diagnosis > Temperature.
Select Internal temperature and read value.
The Internal_Temperature_HiLo.Lo and Internal_Temperature_HiLo.Hi parameters display extreme
values, showing the lowest and highest internal temperatures detected by the device, respectively. In case
of voltage failures and resets, these extreme values are retained.