LT39xx Electronic sensor for level and temperature
6
3 Intended use
3.1 Application area
The unit was especially designed to meet the requirements of machine tool building. It is particularly
suitable for monitoring coolant emulsions (also dirty) as well as cutting and hydraulic oils.
The unit monitors 2 process values: level and temperature.
3.1.1 Restriction of the application area
The unit is not suitable for:
acids and alkalis.
hygienic and electroplating applications.
highly conductive and adhesive media (e.g. glue, shampoo).
granulates, bulk material.
use in grinders (increased risk of formation of deposits).
It is possible that foam of good conductivity is detected as level.
u Check the correct function by performing an application test.
For water and hydrous media with temperatures > 35 °C, install the unit in a climatic tube (Ò
Accessories).
For automatic medium detection:
For media which are very inhomogeneous, separate from each other thus forming separation
layers (e.g. oil layer on water) the following applies:
u Check the correct function by performing an application test.