6.4.3 Installation with fixing bars E80337
6.5 Mounting distances
Operating mode Distance side (A) Distance front (B)
Reading and writing at 100% transmit-
ting power (simultaneous operation)
> 0.6 m > 0.6 m
Reading and writing at 100% transmit-
ting power (alternating operation)
> 0.3 m > 0.3 m
Interference in data communication is avoided if there are no other RFID UHF devices in the
vicinity. If there are other RFID UHF devices in the vicinity:
u The mounting distances between the devices should be as large as possible.
u Use the RSSI filter. (Ò Parameter "Activate RSSI Filter”/39)
u Use the devices in alternating operation.
u Switch the HF field of the device on/off.