ISOBUS gateway CR3122
11
Visualisation
example:
1
2
3
4
5
6
1
2
3
4
1
2
3
4
5
6
7
9
10
8
12
11
Page 1
1
2
3
4
5
6
1
2
3
4
1
2
3
4
5
6
7
9
10
8
12
11
Data Mask 2
8.2.2 Issuing warnings
The function module FB_Warnings issues warning symbols as well as acoustic warnings.
The input parameter wIconWarning<n> defines the type of warning symbol.
The input parameter byStateIcon<n> defines the colour of the warning symbol:
• 0 = white (e.g. off)
• 1 = green (e.g. on)
• 2 = yellow (e.g. warning)
• 3 = red (e.g. alarm)
The input parameter xAcusticWarning switches the acoustic warning on/off. If the acoustic warning
is switched on, the following signal tones are possible:
• If at least one input parameter byStateIcon<n> has the value 2, a warning tone will sound.
• If at least one input parameter byStateIcon<n> has the value 3, an alarm tone will sound.